Termolan Roccia K8 Plus - 1000×600 Rock Wool Panels for ETICS Thermal Insulation
TERMOLANHard panel in rock wool for systems of ETICS coat Format 1000x600 mm, panel water repellent Lambda 0.034 W/mK — excellent thermal insulation Reaction to fire A1 — non-combustible Thicknesses: 100 120 140 160 mm Sale to package, m2 per package clear in the sheet, attached documents available. Large quantities?/strong> The product isem>bulky (long neck / pallet). For multiple orders (multiple rolls or entire pallets) contact us: we will prepare astrong>customized quote with shipping optimization And quantity discounts/strong>. We respond quickly and recommend the most convenient shipping method. This product may incur additional shipping charges.span>
What is it / what is it for?
Termolan Roccia K8 Plus and a rigid panel in biosoluble, water-repellent and uncoated rock wool, CE marked and certified for coat according to ETAG 004. It is suitable for thermal and acoustic insulation of external walls with an external insulation system, as well as for those who require high fire reaction performance.
Why choose it?
- Thermal performance: lambda declared 0.034 W/mK and high R resistances for the available thicknesses.
- Maximum fire safety: Euroclass A1 (non-combustible).
- Acoustics: high absorption coefficient (up to αw 0.95/strong> with thicknesses ≥ 50 mm) and flow resistance 50 kPa s/m²/strong>.
- Durability: water-repellent panel, very low water absorption, mechanical stability.there>
- Practical format: slab 1000x600 mm easy to handle and cut.
Variants and coverage
Sales unit: package (1000x600 mm panels). m2 per pack as follows:
| Thickness (mm) | m2 per package |
|---|---|
| 100 | 28.80 |
| 120 | 24.00 |
| 140 | 9.60pm |
| 6.00 pm |
Tip: Area in m2 / m2 per package + 5–10 percent waste for quick calculation.
Main technical data
- Format : 1000x600 mm; density : ~ 100 kg/m3 .
- Declared thermal conductivity λD : 0.034 W/mK (EN 12667/12939).
- Thermal resistance RD (Reference table): 100 mm 2.90 · 120 mm 3.50 · 140 mm 4.10 · 160 mm 4.70 m2K/W .
- Reaction to fire : A1 (EN 13501-1).
- Water absorption : long term WL(P) < 3.0 kg/m2; short term Wp < 1.0 kg/m2.
- Vapor resistance μ ≈ 1 (breathable material).
- Mechanical : CS(10) ~ 20 kPa ; TR ⟂ at faces ~ 7.5 kPa ; shear strength ~ 20 kPa .
- Acoustics : αw up to 0.95 (thicknesses ≥ 50 mm); air flow resistance 50 kPa s/m2 .
Performance per thickness
| Thickness | R m2K/W | U layer only W/m2K |
|---|---|---|
| 100 mm | 2.90 | 0.34 |
| 120 mmtd> | 3.50 | 0.29 |
| 140 mm | 4.10 | 0.24 |
| 160 mm | 4.70 | 0.21 |
U refers to the insulating layer only, not to the finished wall.
How to use it (step by step installation)
- Preparation of the substrate
Clean, level, and load-bearing substrate. Remove loose parts, old, flaking paint, and surface moisture.
- Gluing panels
Adhesive suitable for ETICS with perimeter bead + dots or continuous spatula application, according to the project.
- Mechanical fixings
Thermal insulation plugs as per diagram and wind zone. Install with staggered joints.
- Armored shaving
Fiberglass mesh embedded in double skimming; then primer and thick finish.
Practical advice
- Cut with a serrated knife or fine-toothed saw; clean off dust before shaving.
- Protect the panels from direct rain during installation; take care of the skirting and base profiles.
- Always check the ETICS system cycles and the designer's instructions.
FAQ
Is it suitable for external coating?
Yes, the product is certified for ETICS applications. Follow the system and the executive project.
How does it react to fire?
Euroclass A1, non-combustible material.
What thickness should I choose?
It depends on the required transmittance. Generally speaking: 100 mm R 2.90, 140 mm R 4.10, 160 mm R 4.70 m2K/W. Check with your technician.
Do you have a large space? We can optimize pricing and logistics with customized delivery.